10020C
Ten-gallon upright wheeled compressor with 5.3 CFM at 90 PSI. It matches the standard 20020's output while occupying less space and carrying less tank reserve.
Review this compressor →Check the equipment you own before buying more. Compare air demand, working pressure and manufacturer limits for the way you actually work.
Free to use. No account needed. Sources included.
A useful answer starts with your job.
Choose your models and working pattern. See the limits before you upgrade.
Check my setup → 02↗Compare airflow, storage and duty limits. Find out what changes between models.
Compare the differences → 03↗Separate at-load use from averages, then calculate demand for your trigger time.
Calculate air demand →Ten-gallon upright wheeled compressor with 5.3 CFM at 90 PSI. It matches the standard 20020's output while occupying less space and carrying less tank reserve.
Review this compressor →The continuous-run version trades a higher published noise figure for a 100% duty rating and defined long-duration limits. Its 90 PSI output is 5.0 CFM, slightly below the standard 20020's 5.3 CFM.
Review this compressor →Twin-tank oil-lubricated model with 4.2 CFM at 90 PSI and two couplers. Its 77 lb weight is a substantial portability consideration.
Review this compressor →Manufacturer pages and manuals are linked with the specifications.
Missing figures stay unknown. They are never filled in with a guess.
See which limit matters and which details you still need to confirm.
A 10- versus 20-gallon choice. Compare the storage difference without treating it as a larger pump.
Compare specifications →Compare the 8-gallon model’s delivery with the 10-gallon, 2 HP model. The flow change matters more than the two extra gallons.
Compare specifications →Both publish 2.2 CFM at 90 PSI. Compare the 2- and 8-gallon tanks, size and source limitations.
Compare specifications →Separate tool consumption while running from a catalog average, then calculate the demand of your own trigger schedule.
Open guide & tool →Calculate an observed pump-on fraction and understand why a published duty percentage is only part of an operating limit.
Open guide & tool →Estimate a theoretical stored-air buffer over a pressure interval and see why tank capacity and pump delivery are separate specifications.
Open guide & tool →No. A larger tank stores more air over the same pressure interval. The pump's delivered CFM determines its published air delivery; tank size alone cannot establish that figure.
Only if the source explicitly identifies that value as at-load consumption. An average may assume an unspecified duty pattern. The matcher keeps those figures separate and asks for missing data.
No. These calculations screen published specifications. Hose losses, fittings, regulator capacity and the installed system need their own checks. Manufacturer application limits still apply.